Hiệu chuẩn Oil Mist Detector - Schaller / Visatron

logo

Hotline: 0913 917 925

Vietnam English
Hiệu chuẩn Oil Mist Detector - Schaller / Visatron
24/03/2025 09:58 PM 16 Lượt xem

    A. Kit – Maintenance (Spare Part kit 1)

    Item P/N Description Quantity
    1 365206 Filter for Pressure Reducer 1
    2 365197 Disc Sinterbrass 22x2, Filter 2
    3 366717 Filter cartridge (Optional) 1
    4 365208 O-Ring-ISO3601-1-A-9,0x4,5-N 1
    5 365198 Lock ring DIN 472 - 22 x 1 - S 2
    6 355636 Gasket for Inspection cover for air scav 1

     

    B. Kit – Service VN215 (Spare Part kit 5)

    Item P/N Description Quantity
    1 330721   Gasket for valve box 1
    2 330482 Gasket for Measuring Head 1
    3 355636 Gasket for Inspection cover for air scav 1
    4 200211 Measuring head suspension, top 2
    5 200212 Measuring head suspension, bottom 2
    6 365206 Filter for Pressure Reducer 1
    7 365197 Disc Sinterbrass 22x2, Filter 2
    8 365198 Lock ring DIN 472 - 22 x 1 - S 2
    9 365193 Flexible bellow Base Plate/Meas. Head 2
    10 480824 Sunk.screw ISO 10642 - M3 x 12 - 8.8 gv 4
    11 366717 Filter cartridge (Optional) 1
    12 365208 O-RING 9,0X4,5 NBR70 Screw Pressure Reducer 1
    13 365449 O-RING 8,0X2,5 Screw Throttle 1
    14 365954 O-RING 4,0 X 1,75 NBR70 Throttle 1
    15 330543 Seal for airflow- pump 3
    16 360132 Oil Return Gasket VN116/215 1
    17 360133 Oil mist Gasket Valvebox VN116/215 1
    18 360079 Rubber plate for tube connection 2
    19 360194 Lock plug 5

     

    C. Kit – Cleaning (Spare Part kit 2)

    Item P/N Description Quantity
    1 270090 (10035) Bottle with cleaning liquid 1
    2 452176 Cotton Stick for Infra-Red Lens 20
    3 190003 Needle for Air Bores 1

     

    D. Pressure gauge with couplings

     

    E. Kit - Visatron Function Test - VN115/116/215 – VN87-EMC/87Plus/87Plus-EX/93

    F. MAINTENANCE PLAN – VN/87 & VN/87 EMC

    Procedure/Interval: What to do:
    Procedure 1 / Every month

    Check the negative pressure with u- tube manometer. Adjust if necessary! Setting level is 60,00 mmH2O!

    Replace the sintered bronze air filter/ fresh air filter (part no. 10042) in the measuring head.

    Clean the fresh air bores in the measuring head. Use the cleaning needle (part no. 10135)

    Clean both infra-red sensor glasses in the measuring head with cotton pins and technical alcohol.

    Procedure 2 / Every 4 months

    Replace sintered bronze filter and o- ring in the pressure regulator
    Procedure 3  / Yearly

    Replace maintenance kit for base plate (100150, 100151 or 100152). Clean the inside/ outside of base plate.

    Check performance of pressure regulator- replace parts if necessary!

    Clean suction pipes/ pipe system and siphon blocks with compressed air!
    Procedure 4 / Every 4 years

    Replace measuring head. Use our Exchange Pool Service (ExP) for this procedure! NOTE: When ordering an exchange unit – always inform us about engine type!

    Replace maintenance kit for base plate (100150, 100151 or 100152). Clean the inside/ outside of base plate.

    Check performance of pressure regulator- replace parts if necessary!

    Clean suction pipes/pipe system and siphon blocks with compressed air!

    Check sampling funnels/pipe system.

    If your system have siphon blocks:

    Replace rubber inserts and o-rings in siphon blocks (Part no.: 10095/360106 & 365287.

    If you are ordering a complete exchange oil mist detector unit, there is no need to replace maintenance kit for base plate.

     

    G. MAINTENANCE PLAN – VN/87PLUS

    Procedure/Interval: What to do:
    Procedure 1 / Every month

    Check the negative pressure with u- tube manometer. Adjust if necessary! Setting level is 60,00 mmH2O!

    Replace the sintered bronze air filter/ fresh air filter (part no. 10042) in the measuring head.

    Clean the fresh air bores in the measuring head. Use the cleaning needle (part no. 10135)

    Clean both infra-red sensor glasses in the measuring head with cotton pins and technical alcohol.

    Procedure 2 / Every 4 months

    Replace sintered bronze filter and o- ring in the pressure regulator

    Procedure 3 / Yearly

    Replace maintenance kit for base plate (100150, 100151 or 100152). Clean the inside/ outside of base plate.

    Check performance of pressure regulator- replace parts if necessary!

    Clean suction pipes/ pipe system and siphon blocks with compressed air!

    Procedure 4 / Every 4 years

    Replace measuring head. Use our Exchange Pool Service (ExP) for this procedure! NOTE: When ordering an exchange unit – always inform us about engine type!

    Replace maintenance kit for base plate (100150, 100151 or 100152). Clean the inside/ outside of base plate.

    Check performance of pressure regulator- replace parts if necessary!

    Clean suction pipes/pipe system and siphon blocks with compressed air!

    Check sampling funnels/pipe system.

    If your system have siphon blocks:

    Replace rubber inserts and o-rings in siphon blocks (Part no.: 10095/360106 & 365287).

    If you are ordering a complete exchange oil mist detector unit, there is no need to replace maintenance kit for base plate.
    Zalo